Wilks油脂分析仪
HONEYWELL(霍尼韦尔)
a
b
企业名:北京商思达电子销售二部
类型:生产制造商
电话:
0755-83370245
83376489
83376549
手机:13902971329
联系人:销售部
邮箱:1295084882@qq.com
地址:北京北京市北京海淀区中发电子大厦12097
InfraCal 2 Analyzers
THz组件
THz发生器
THz探测器
THz时域光谱仪
THz成像
UV-LED 氘钨灯光源
飞秒光纤激光器
激光二极管 激光芯片
半导体激光器
气体激光器
单频激光器
脉冲激光器
连续激光器
可调谐激光器
控制器 驱动器
光谱分析仪器
光束质量分析仪
位敏探测系统
激光准直仪
激光功率计
激光波长计
激光观察仪 显示卡
激光防护眼镜
透镜 准直镜 扩束镜
高端滤光片
光电探测器
单光子计数器
光纤
压力传感器
体布拉格光栅
偏振片
可饱和吸收镜
SERS拉曼芯片
Measuring Oil In Water & Soil
ASTM D7066, ISO 9377-2, EPA 1664, 413.2, & 418.1
FOG in wastewater
TPH in soil
Testing produced water on offshore or onshore oil rigs
Monitoring refinery or industrial plant wastewater effluents
Measuring FOG discharge levels
Checking oil/water separation systems
Measuring oil in drilling mud/cuttings
Testing for residual oil on pre-cleaned metal components
Determining the purity level of reclaimed solvents
Onsite testing of soil at remediation sites
Model |
InfraCal HATR-T2 |
InfraCal CVH |
InfraCal 2 ATR-SP |
InfraCal 2 TRANS-SP |
Min detection Water |
8 ppm |
2 ppm |
0.3 ppm |
0.1 ppm |
Min detection Soil |
40 ppm |
10 ppm |
3 ppm |
1 ppm |
Solvent |
Hexane, Pentane, Cyclohexane, Vertrel MCA |
Perchloroethylene, S-316, Freon-113 |
Hexane, Pentane, Cyclohexane, Vertrel MCA |
Perchloroethylene, S-316, Freon-113 |
Components measured |
Hydrocarbons with boiling point higher than solvent |
All hydrocarbons |
Hydrocarbons with boiling point higher than solvent |
All hydrocarbons |
Method complies |
NA |
ASTM D7066, EPA 413.2 EPA 418.1 |
NA |
ASTM D7066, EPA 413.2 EPA 418.1 |
Method compares |
EPA 1664, ISO 9377-2 |
EPA 1664, ISO 9377-2 |
EPA 1664, ISO 9377-2 |
EPA 1664, ISO 9377-2 |
Volatile componets |
Loses |
Includes |
Loses |
Includes |
Data acquisition |
Printer from Wilks |
Printer from Wilks |
Internal data storage & export |
Internal data storage & export |
Calibrations |
Single |
Single |
Multiple |
Multiple |
Display |
4 character LED |
4 character LED |
Touch screen |
Touch screen |
Password protection |
No |
No |
Yes |
Yes |
Battery pack |
External |
External |
Internal |
Internal |
Others |
Solvents lighter than water, sample collected form container top |
Solvents heavier than water, requires separatory funnel or septa cap vial |
Solvents lighter than water, sample collected form container top |
Solvents heavier than water, requires separatory funnel or septa cap vial |
Model |
P/N |
Description |
Min Detection 8 ppm |
405-1009 |
Includes 100 mrcroliter sypringe, Un-calibrated |
InfraCal Model HATR-T2 |
405-1009-44 |
Factory calibrated using 403-1044 |
403-1044 |
TOG/TPH calibration standard set |
|
405-1009-72 |
Factory calibrated using 403-1072 |
|
403-1072 |
FOG/TOG calibration standard set |
|
403-1067 |
InfraLog serial printer |
|
403-0013 |
Carrying case |
|
403-0003 |
External 12V battery pack |
|
403-0002 |
12V automotive power adapter cable |
|
403-0005 |
Dust cover |
|
403-1011 |
Field sampling kit |
|
Min Detection 2 ppm |
405-0003/12 |
Includes set of 4-10mm cuvettes, Un-calibrated |
InfraCal Model CVH |
405-0003/12-41 |
Factory calibrated using 403-1041 |
403-1041 |
S-316 TOG/TPH calibration standard set |
|
405-0003/12-40 |
Factory calibrated using 403-1040 |
|
403-1040 |
S-316 FOG/TOG calibration standard set |
|
405-0003/12-78 |
Factory calibrated using 403-1064 |
|
403-1064 |
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set |
|
403-0012 |
Set of 4-10mm quartz cuvette cells |
|
403-1067 |
InfraLog serial printer |
|
403-0013 |
Carrying case |
|
403-0003 |
External 12V battery pack |
|
403-0002 |
12V automotive power adapter cable |
|
403-0005 |
Dust cover |
|
403-1063 |
Field sampling kit |
|
Min Detection 0.3 ppm |
405-2034 |
Includes set of 4-10mm cuvettes, Un-calibrated |
InfraCal 2 Model ATR-SP |
405-2034-81 |
Factory calibrated using 403-1081 |
403-1081 |
Hexane TOG/TPH calibration standard set (Low range) |
|
405-2034-44 |
Factory calibrated using 403-1044 |
|
403-1044 |
Hexane TOG/TPH calibration standard set (High range) |
|
405-2034-8144 |
Factory calibrated using 403-1081 and 403-1044 |
|
405-2034-72 |
Factory calibrated using 403-1072 |
|
403-1072 |
Hexane FOG/TOG calibration standard set |
|
403-0013 |
Carrying case |
|
403-1011 |
Field sampling kit |
|
Min Detection 0.1 ppm |
405-2035 |
Includes set of 4-10mm cuvettes, Un-calibrated |
InfraCal 2 Model TRANS-SP |
405-2035-80 |
Factory calibrated using 403-1080 |
403-1080 |
S-316 TOG/TPH calibration standard set (Low range) |
|
405-2035-41 |
Factory calibrated using 403-1041 |
|
403-1041 |
S-316 TOG/TPH calibration standard set (High range) |
|
405-2035-8041 |
Factory calibrated using 403-1080 and 403-1041 |
|
405-2035-40 |
Factory calibrated using 403-1040 |
|
403-1040 |
S-316 FOG/TOG calibration standard set |
|
405-2035-79 |
Factory calibrated using 403-1079 |
|
403-1079 |
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set (Low range) |
|
405-2035-78 |
Factory calibrated using 403-1078 |
|
403-1078 |
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set (High range) |
|
405-2035-7978 |
Factory calibrated using 403-1079 and 403-1078 |
|
403-0012 |
Set of 4-10mm quartz cuvette cells |
|
403-0013 |
Carrying case |
|
403-1063 |
Field sampling kit |
|
403-1083 |
Field sampling kit for sub-ppm |
企业名:北京商思达电子销售二部
类型:生产制造商
电话:
0755-83370245
83376489
83376549
手机:13902971329
联系人:销售部
邮箱:1295084882@qq.com
地址:北京北京市北京海淀区中发电子大厦12097