Electrical
|
Impedance
|
50 Ω
|
Frequency Range
|
0 - 11 GHz
|
Voltage Rating
|
1,500 volts peak
|
VSWR
|
MIL-C-39012 straight connectors: 1.3 max 0-11 GHz
MIL-C-39012 right angle connectors: 1.35 max 0-11 GHz
|
Dielectric Withstanding Voltage
|
2,500 volts rms
|
Insulation Resistance
|
5,000 MΩ minimum
|
Center Contact Resistance
|
1.0 mΩ
|
Outer Contact Resistance
|
0.2 mΩ
|
RF Leakage
|
-90 dB minimum at 3 GHz
|
Insertion Loss
|
.15 dB maximum at 10 GHz
|
Mechanical
|
Mating
|
5/8-24 threaded coupling
|
Braid or Jacket Cable Affixment
|
All crimps: hex braid crimp
Clamps: screw-thread nut and braid clamp
|
Center Conductor Cable Affixment
|
Crimp: crimp or solder
All others: solder only
|
Captivated Contact
|
All crimps unless specified otherwise
|
Cable Retention
|
Crimps: 60-120 lbs
Clamps: 30-70 lbs
|
Material
|
Male Contacts
|
Brass, silver or gold plated
|
Female Contacts
|
Phosphorous bronze or beryllium copper, silver or gold plated
|
Other Metal Parts
|
Brass with ASTROplate® finish; M39012 has silver finish
|
Insulators
|
TFE, copolymer of styrene or glass-TFE (hermetic seal)
|
Weatherproof Gaskets
|
Silicone rubber of synthetic rubber
|
Crimp Ferrule
|
Copper
|
Environmental
|
Temperature Range
|
TFE: -65°C to +165°C
|
Weatherproof
|
All series N with gaskets are weatherproof
|
Hermetic Seals
|
Pass helium leak test of 2x10-8 cc/sec
|
Pressurized Shock
|
Compression seal MIL-STD-202, method 213
|
Vibration
|
MIL-STD-202, method 204, test condition B
|
Moisture Resistance
|
MIL-STD-202, method 106
|
Corrosion
|
MIL-STD-202, method 101, test condition B
|
Temperature Cycling
|
MIL-STD-202, method 102, test condition C
|
Altitude
|
MIL-STD-202, method 105, test condition C
|
Military
|
MIL-C-39012
MIL-A-55339
|
Where applicable
|