Output Voltage Range 0 to &plu*n;5 kV DC or peak AC.
Output Current Range 0 to &plu*n;20 mA DC or peak AC. (See Automatic Power Limit feature for limitations.)
Input Voltage Range 0 to &plu*n;5 V DC or peak AC.
Input Impedance 20 kohm, nominal.
DC Voltage Gain 1000 V/V.
Gain Accuracy Better than 0.1% of full scale.
Offset Voltage Better than &plu*n;2 V.
Output Noise Less than 3.5 V rms (measured using the true rms feature of the Hewlett Packard Model 34401A di*al multimeter).
Slew Rate (10% to 90%, t*ical) Greater than 500 V/µs.
Large Signal Bandwidth (1% distortion) DC to greater than 15 kHz.
Small Signal Bandwidth (-3dB) DC to greater than 20 kHz.
Settling Time (to 1%) Less than 100 µs for a 0 to 5 kV step.
Automatic Power Limit Automatically limits the internal power dissipation to protect the PD06087 from overheating. The following graph illustrates the automatic power limit