您现在的位置:维库电子市场网 > 元器件 > 仪器/仪表 > 其他未分类

美国RSD RS-320胸/肺模体

美国RSD RS-320胸/肺模体
美国RSD RS-320胸/肺模体
  • 型号/规格:

    RS-320

  • 品牌/商标:

    RSD

  • 保修:

    一年

  • 品牌:

    RSD

  • 型号:

    RS-320

  • 进口:

    美国

普通会员
  • 企业名:深圳市净康科技有限公司

    类型:经销商

    电话: 075528917660

    手机:18123914686

    联系人:张女士

    邮箱:18123914686@163.com

    地址:广东深圳深圳市龙岗区南湾街道吉厦社区沙平北路111号

产品分类
商品信息

Alderson肺/胸部模体是一个专门的模体,提供高度的现实主义在胸部X光片。肺/胸部模体模型带有可拆卸的隔膜肺对插入物,无冠状动脉。


RS-320特点和优点:


  • 广泛的血管细节
  • 不同程度的血管对比可用
  • 可互换的正常和病理性肺
  • 从颈部延伸到隔膜下方
  • 选择动物肺以匹配成年男性的大小。
  • 允许肺交换,并提供无限数量的配置和疾病模拟。
  • 肺动脉注射血液当量塑料。
  • 提供血液当量肺动脉,或添加低或高对比剂。



RSD RS-320胸部模体为了证明不同的病理状况,纳入了五种标准病状(可选项目):

di一个左肋jian端有两个连续的0.5厘米结节

0.6厘米结节叠加在左下叶大血管

1.5厘米结节,左侧纵隔阴影

0.6厘米结节与右肺动脉混合

肺右下叶

保修信息:1年保修


RS-310:Lung/Chest Phantom with permanently sealed diaphragm

RS-315:Lung/Chest Phantom with permanently sealed diaphragm and left coronary artery

RS-320:Lung/Chest Phantom with removeable diaphragm lung pair insert without coronary artery

RS-330:Lung/Chest Phantom with removeable diaphragm lung pair insert with coronary artery

RS-340:Lung/Pair insert without coronary artery

RS-345:Lung/Pair insert with coronary artery

LUNG/CHEST PHANTOMS

Extensive Vascular Detail
Different Degrees of Vascular Contrast Available
Interchangeable Normal and Pathological Lungs
Developed in conjunction with the University at California, Irvine's Department of Radiological Sciences, the Alderson Lung/Chest Phantom is a specialized phantom, providing a high degree of realism in chest radiography.

The Alderson Lung/Chest Phantom extends from the neck to below the diaphragm. It is molded about a male skeleton, corresponding to the external body size of a patient, 5 feet, 9 inches (175 cm) tall and weighing
162 lbs (73.5 kg). RSD materials are equivalent to natural bone and soft tissues.

Animal lungs are selected to match the size of an adult male. Lungs are fixed in the inflated state and are molded to conform to the pleural cavities of the phantom. The pulmonary arteries are injected with a blood equivalent plastic.

The Lung/Chest Phantom with simulated left coronary artery reveals several areas of coronary artery irregularity and narrowing.

To demonstrate different pathological conditions, five standard pathologies are incorporated: Please call for pricing.

RS-320产品实拍图:




联系方式

企业名:深圳市净康科技有限公司

类型:经销商

电话: 075528917660

手机:18123914686

联系人:张女士

邮箱:18123914686@163.com

地址:广东深圳深圳市龙岗区南湾街道吉厦社区沙平北路111号

提示:您在维库电子市场网上采购商品属于商业贸易行为。以上所展示的信息由卖家自行提供,内容的真实性、准确性和合法性由发布卖家负责,请意识到互联网交易中的风险是客观存在的。请广大采购商认准带有维库电子市场网认证的供应商进行采购!

电子元器件产品索引: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9